Post processing static analysis
Last reviewed version: 2.18.0Open static_01.avz in AquaView and plot axial forces. Axial forces are found in Result > Local section forces > Axial force [N].
Axial forces can be compared between element A and B of the rollers. For static considerations the difference is about 5 N for both rollers. The beam should remain in the waterline without significant displacements.
Ok, so now we know that the system works for static situations. Let us return to AquaEdit and apply current and waves and conduct a dynamic analysis.